EasyMax VSelf-MonitoringBlood Glucose SystemUSER’S MANUAL

Pagina 2 - User’s Manual

9 Description of Sound WHEN the meter will speak WHAT the meter will say Tune on. Turn-on music and greeting Tone. Setting Language / Setting Volume

Pagina 3 - Intended Use

10 Table of Contents Chapter 1: Understanding Your Meter …...

Pagina 4

11 Symptoms of High or Low Blood Glucose...34 Comparing

Pagina 5 - Do you need Help?

12 Chapter 1: Understanding Your Meter The EasyMax V Blood Glucose Meter Display- Shows results, messages, and results stored

Pagina 6

13 The EasyMax V Accessories Blood Glucose Test Strip Test Strip Bottle Expiration Date Strip Insert Direction Hand Hold Area Edge to Apply Sample

Pagina 7

14 Installing Batteries 1. Open the battery door on the back of the meter by pushing the tab in the direction of the arrow

Pagina 8 - Health-Related Information

15 Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory.

Pagina 9 - Explanation of Symbols

16 Setting The Language and Volume—First Time Use 1. Press  to adjust the language.(En= English, Es = Spanish) 2. And press  to confirm the

Pagina 10 - Description of Sound

17 Using EasyMax V Blood Glucose Test Strip  Use only with EasyMax V Blood Glucose Meter.  Run a control solution test every time you open a new bo

Pagina 11 - Table of Contents

18 Chapter 2: Control Solution Testing Why Run A Control Solution Test We recommend that you run the EasyMax V Normal control test because it lets you

Pagina 12

1 EasyMax V Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucose mete

Pagina 13 -

19 About The Control Solution  Use only with EasyMax V test strips.  Write the date you opened the bottle on the bottle label. The control solution

Pagina 14 - Test Strip Bottle

20 Running A Control Solution Test You need the meter, a test strip, and control solution. 1. Put a test strip into the meter in the direc

Pagina 15 - Installing Batteries

21 6. Touch the drop at the tip of the test strip. 7. The meter starts to count down from 5 seconds and then shows the result. 8. Do not

Pagina 16

22 Understanding Control Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions. The result

Pagina 17

23 Troubleshooting Checks Action 9 Was the test strip exposed to open air for a long period of time? Repeat the

Pagina 18

24 Chapter 3: Testing Your Blood Glucose Using The Lancing Device  The best depth setting is the lowest number that draws enough blood for a test. Tr

Pagina 19

25 Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew

Pagina 20 - About The Control Solution

26 3. Recap the front cap.4. Select the desired penetration depth. Note: Select 1-2 for soft or thin skin. 3 for average. 4-5 for thick o

Pagina 21

27 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do n

Pagina 22

28 Running A Blood Glucose Test With Blood From Your Fingertip 2. Put a test strip into the meter in the direction of the arrow. The meter t

Pagina 23

2 Dear EasyMax V SMBG System Owner, Thank you for using the EasyMax V Self-Monitoring Blood Glucose (SMBG) System. We designed this system to be depe

Pagina 24

29 5. Gently squeeze and/or massage your fingertip until a round drop of blood on your fingertip. 6. Touch the blood drop at the tip of the t

Pagina 25

30 Alternate Site Testing (AST) Understanding Alternate Site Testing Consult your health care professional before you begin using the forearm fo

Pagina 26 - 1. Unscrew the Cap

31 What to do: Fingertip test only:  If sick  If blood glucose is low  After exercising  Two hours or less after eating

Pagina 27 - 3. Recap the front cap

32 1. Massage the puncture area of forearm for a few seconds. 2. Press and hold the device with clear adjustable tip against the forearm. 3. Press the

Pagina 28

33 Discarding Used Lancets 2. Please discard used disposable lancets according to the recommendations of your healthcare professional. 1

Pagina 29

34 Understanding Your Test Results The EasyMax V Blood Glucose test strips are plasma referenced and calibrated for easier comparison to lab results.

Pagina 30

35 Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and deci

Pagina 31 - Alternate Site Testing (AST)

36 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results. Your blood

Pagina 32 - Fingertip test only:

37 Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test. You

Pagina 33

38 Viewing & Deleting Test Results The meter provides 7, 14, 30, 60 and 90 days averaging to help track your blood glucose trend soundlessly.

Pagina 34 - Discarding Used Lancets

3 Standard Accessories Your new EasyMax V Blood Glucose meter and accessories work together to measure the amount of glucose in your blood. The system

Pagina 35 - Unusual Test Results

39 Meter Setup Using The Set Mode By using the set mode, you can personalize your meter to suit your needs. Here are the features you can customiz

Pagina 36

40 Chapter 5: Maintenance and Troubleshooting Installing Batteries The meter uses two alkaline 1.5V (AAA) batteries. Batteries will normally last for

Pagina 37

41 Cleaning Your Meter Caring for your EasyMax V SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, bloodstain

Pagina 38 - Memory, Storing Test Results

42 Maintenance And Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn it

Pagina 39

43 Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local d

Pagina 40 - Meter Setup

44 System fault Action: Replace the batteries first. If Err appears again, please call Customer Service toll-free 866-994-3345. Test result

Pagina 41

45 The ”HF” and thermometer icon appears. Temperature is too high, outside the required range of 50°F - 104°F (10°C - 40°C). Action: Relocate the me

Pagina 42 - Cleaning Your Meter

46 Chapter 6: Technical Information Specifications Brand name EasyMax V Blood Glucose Meter Range 20 - 600 mg/dL Test time 5 seconds Memory sets

Pagina 43 - Cleaning Your Lancing Device

47 Limitation The test strips are used for fresh capillary whole blood samples. 1. DO NOT use neonate blood sample. 2. Extreme humidity may affect

Pagina 44

48 10. Critically ill patients should not be tested with home-use blood glucose meters. 11. Interfering Substances depend on the concentration. Elev

Pagina 45

4 Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diab

Pagina 46

49 Device Information EasyMax V SMBG System, EasyMax V Blood Glucose Test Strips, EasyMax V Blood Glucose Meter, EasyMax V Normal Control Solution,

Pagina 47 - Specifications

50 Lancet Meets the requirements of MDD 93/42/EEC Manufacturer: SAE HAN MEDICAL CORP. # 700-113 PUB GOT-DONG, IL SAN-GU, GOYANG-CITY, KYUNGGI-DO, KOR

Pagina 48 - Limitation

5 Important Information About Your New Meter  EasyMax V blood glucose meter is designed and approved for testing fresh capillary blood from finger

Pagina 49

6  Remove batteries if the meter will not be used for one month or more.  Warning for potential biohazard: Healthcare professionals using this sys

Pagina 50 - Device Information

7 Health-Related Information  If you are very dehydrated, urinating frequently, low blood pressure, shock or hyperosmolar hyperglycemic nonketotic

Pagina 51 - Warranty

8 Explanation of Symbols  Left button  Right button Date Memory Time Insert a test strip Result amount Battery Unit Volume English Temperat