EasyPlus mini Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucose met
10 Chapter 1: Understanding Your Meter The EasyPlus mini Blood Glucose Meter The Overview of the Display Meaning A Year, month and
11 The Overview of the Meter: A. Manufacturer information B. Smart Jog Wheel C. Serial number D. Display E. Anti-Slippery Pad
12 Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you use the meter memory or if you want to
13 4. Press inwards and release the wheel to set the month. The date will then flash. Repeat step 3 to set the date.5. Press inwards and re
14 Checking Your System A new check strip is included with your meter. 1. Make sure your check strip is inserted. The meter will turn on automatic
15 Coding Your Meter A new Code Card is inside each new box of test strips. Code your meter every time you open a new box of test strips. 1
16 Using EasyPlus mini Blood Glucose Test Strip Use only with EasyPlus mini Blood Glucose Meter. Code your meter and run a control test every time
17 Chapter 2: Control Solution Testing Why Run A Control Solution Test Running a control test lets you know that your meter and test strips are workin
18 About The Control Solution Use only with EasyPlus mini test strips. Write the date you opened the bottle on the bottle label. The control solut
19 Running A Control Solution Test You need the meter, a test strip, and control solution 2. If you can’t see the code number, take the
Dear EasyPlus mini SMBG System Owner, Thank you for using the EasyPlus mini Self-Monitoring Blood Glucose (SMBG) System. We designed this system to be
20 3. Place the meter on a flat surface, like a table.4. Remove the control solution bottle cap and wipe the tip of the bottle with a tiss
21 6. A result appears on the display. Don’t remove the test strip yet. Check if the reading falls within the range printed on the test strip
22 Understanding Control Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solution. The result you get s
23 Troubleshooting Checks Action Was the test strip exposed to open air for a long period of time? Repeat the c
24 Chapter 3: Testing Your Blood Glucose Using The Lancing Device The best depth setting is the lowest number that draws enough blood for a test. Tr
25 Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Take the ca
26 3. Recap the front cap.4. Select the desired penetration depth. Note: Select 1-3 for soft or thin skin, 4-5 for average, and 6-8 for thi
27 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not
28 Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap and warm water. Rinse and dry thoroughly. 2
29 4. Swab the blood collection area on your finger with an alcohol swab. Please wait at least 5 seconds until the intended area is dry an
Standard Accessories Your new EasyPlus mini Blood Glucose meter and accessories work together to measure the amount of glucose in your blood. The syst
30 7. Gently squeeze your finger to assist the flow of blood. This helps you get a blood drop. Touch the drop to the tip of the tran
31 Alternative Site Testing (AST) Understanding Alternative Site Testing Alternative site results may differ from the fingertip when glucose lev
32 Caution: Talk with your healthcare professional before you test palm or forearm. Do NOT ignore symptoms of high or lo
33 1. This pictures shows areas where alternative site testing is allowed. 2. Massage the puncture area of palm for a few seconds. Running A Blood G
34 4. Press the trigger button to activate the lancing device. 5. Hold the device against palm and increase pressure until the blood sample size is su
35 1. Massage the puncture area of forearm for a few seconds. 2. Press and hold the device with one clear adjustable tip against the forearm. 3. Press
36 Discarding Used Lancets 1. Unscrew and remove the adjustable cap. Without touching the used lancet, stick the lancet tip into its prote
37 Expected Values* The EasyPlus mini Blood Glucose test strips are whole-blood referenced and calibrated for easier comparison to lab results. The no
38 Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and deci
39 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results. Your blood
Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diabet
40 Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test. You
41 Viewing & Deleting Test Results 1. Press inwards and hold the wheel until turning the meter on. 2. Push the wheel up or down
42 Setting The Alarm The meter can set up to 4 alarms, allowing you to control your test times according to your requirements. he 1. Press
43 5. If the time is set at 12:00 AM, push up or down twelve times to set at "12". Press inwards to confirm. 7. If you don
44 8. You can then set up other alarms fitting as wanted. Please repeat the step 1 to 7, and finally press inwards to confirm the setti
45 Chapter 5: Maintenance and Troubleshooting Installing Batteries The meter uses two alkaline 1.5V (AAA) batteries. Batteries will normally last for
46 Cleaning Your Meter Caring for your EasyPlus mini SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, bloods
47 Maintenance And Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn
48 Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, call our Customer Service T
49 System fault Action: Replace the batteries first. If 001 ERROR appears again, please call Customer Service toll-free 1-866-203-2761. Syst
Important Information About Your New Meter EasyPlus mini blood glucose meter is designed and approved for testing fresh capillary whole blood samp
50 The "Ht" and thermometer icon appears. Temperature is too high, outside the required range of 50°F ~104°F (10°C ~40°C). This ale
51 Test result is higher than 600 mg/dL. Action: Test again. If the result is still the same, please contact your healthcare professional. Th
52 Chapter 6: Technical Information Specifications Brand name EasyPlus mini Blood Glucose Meter Range 20~600 mg/dL Response time 5 seconds Memory
53 Limitation The test strips are used for fresh capillary whole blood samples. 1. DO NOT use neonate blood sample. 2. Extreme humidity may affect
54 10. Critically ill patients should not be tested with home-use blood glucose meters. 11. Interfering Substances depend on the concentration. The
55 Device Information EasyPlus mini SMBG System, EasyPlus mini Blood Glucose Test Strips, EasyPlus mini Blood Glucose Meter. Manufacturer: EPS BIO TE
56 Lancet Meets the requirements of MDD 93/42/EEC Manufacturer: SAE HAN MEDICAL CORP. # 700-113 PUB GOT-DONG, IL SAN-GU, GOYANG-CITY, KYUNGGI-DO, KOR
Warning for potential biohazard: Healthcare professionals using this system on multiple patients should be aware that all products or objects that c
Health-Related Information If you are experiencing dehydration, frequent urination, low blood pressure, shock or hyperosmolar hyperglycemic nonket
Table of Content Chapter 1: Understanding Your Meter ….......
Unusual Test Results ……………………………...........…………………………………...37 Symptoms Of High Or Low Blood Glucose …..... ...
Comentarios a estos manuales